eCassims.com  Solutions close control conditioning  


 

 

Server rooms
Telecom & switching stations

Laboratories

Dealer Rooms & Clean Rooms

Printing & Graphics Areas

Control & Instrumentation Rooms

Museums & Art Galleries

High Tech Office Suites

 

Precision AirConditioning

vs

Building or Comfort Systems

Designed to operate 8,760 hrs/yr

Perhaps 1,200 hours for office hours

Purpose designed system parameters

IT equipment often installed after occupancy

Easier & lower-cost upgrade path

Upgrades to capacity usually expensive

Higher efficiency on sensible cooling

Designed to cool people & remove humidity

Minimal humidification costs

30-40% of operating $'s removes humidity

Reduced operating costs - up to 60% lower

Out-of-hours operation not desirable

Stand-by capability

Limited stand-by - if at all

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

 

C3 for systems critical environments

Information technology is developing at such a dazzling speed it is sometimes difficult to keep track. But there is no doubt that its application is becoming more and more critical to our lives.

For businesses that need to store, process and distribute information it is hard to imagine how it can be run efficiently without the aid of an efficient Information System. The importance of the information system truly cannot be over - emphasized.

Computer and telecommunication equipment are the corner stones on which information systems are built, and hence their reliability and efficiency will have a direct impact on efficiencies of a company's information systems. Also, although in no way can be compared to the value of the data and applications that these equipment store and process, these equipment are itself very expensive items. The importance to ensure that they can operate reliably is obvious.

 

 

 

 

 

 

 

Electronic equipment are characterized with densely installed high speed digital processors which generates large amount of heat energy, This heat must be removed effectively or else the reliability and life span of the equipment would be greatly affected.

However, merely removing the heat is only part of the solution. The air conditioning systems used must be able to control the air temperature and humidity within a close range to deal with static electricity build up and minimise expansion and contraction of circuitry due to temperature fluctuations. It must have highly efficient filtration systems to keep the air clean, and as the information systems typically operate continuously, its design and construction must be of extremely high reliability. It must also be energy efficient to keep the operation cost to the minimum.

All these are unique requirements for critical space cooling, and ordinary air conditioners used solely for human comfort is not the answer. Close Control Conditioning or "C3" systems must be used.

 

 

 

 

 